dc.description.abstractVisual comfort is a subjective response to the amount and light quality within the workplace at a certain time. The idea behind visual comfort revolves around person’s capability to regulate the light levels surrounding him. Having very small or excessively high amount of light can lead to visual discomfort. This paper investigated and assessed to which extent the use of geometric configurations in the classical architectural elements can fulfill the need for adequate lighting required for acceptable visual comfort. Domes as a classical architectural element function as a main daylight source and at the same time aesthetically pleasing and give the feeling that the room is bigger in size. The dome was chosen as the classical element to be tested in this paper, choosing a building at the University of Sharjah to be the case study. The research used simulation tools including Revit with Insight Plugin and IES with Radiance Plugin Software which will be used to get the glare evaluation and visual comfort index using Daylight Glare Probability metric (DGP), Glare Threshold Differential (GTD), illuminance, Spatial Daylight Autonomy (𝑠𝐷𝐴300/50%) and Annual Sunlight Exposure (𝐴𝑆𝐸1000/250) for different simulated scenarios. The scenarios included cases where the dome was modified and its geometrical configuration were changed in order to enhance the dome capabilities, which included changes in dome’s diameter, drum’s height, and glazing area to drum area percentage. Results showed that, comparing modification done in each variable, highest effect is the glazing percentage =100%, followed by glazing percentage=25%, then drum height =4m, glazing percentage=15% and drum height=3m are almost the same, followed by diameter of 18m and last diameter of 14m. If the dome is already constructed and needed enhancement its preferable to increase the amount of glazing within the dome since it makes the highest impact compared to other variables, with taking into consideration the values of sDA and ASE by testing them in simulations since increasing the glazing percentage increases the possibility of glare to occur. If the architect/designer wants better, uniform and equal daylight distribution bigger diameter can provide it although it doesn’t increase the illuminance levels that much, but if he is looking for higher illuminance level and ensure the glare won’t occur the designer should go with higher height. Equations were concluded showing the relationship of the glazing area with sDA and ASE values. Suggested recommendations for preferred combination of height, diameter and glazing percentage for dome's design and indicated the best orientation per date and time in order to prevent disturbing/intolerable glare.en_US
dc.identifier.other20181357
dc.identifier.urihttps://bspace.buid.ac.ae/handle/1234/1624
dc.language.isoenen_US
dc.publisherThe British University in Dubai (BUiD)en_US
dc.subjectdomeen_US
dc.subjectilluminanceen_US
dc.subjectglareen_US
dc.subjectarchitectural elementsen_US
dc.subjectvisual comforten_US
dc.subjectdaylighten_US
dc.subjectreviten_US
dc.subjectIESen_US
dc.subjectdaylight glare probabilityen_US
dc.subjectglare threshold differentialen_US
dc.subjectspatial daylight autonomyen_US
dc.subjectannual sunlight exposureen_US
dc.titleThe Effect of Daylight on Visual Comfort: The Case of the Dome as a Classical Architectural Element.en_US
dc.typeDissertationen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
20181357.pdf
Size:
29.31 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: