Projects (IT & Engineering)
Permanent URI for this community
Browse
Browsing Projects (IT & Engineering) by Subject "hot climate"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item The Effect of Shading Devices on the Energy Consumption of Buildings: A Study on an Office Building in Dubai(The British University in Dubai (BUiD), 2013-04) Yassine, FarahThe world is witnessing a global movement working towards the goal of decreasing emissions that are causing the global warming phenomenon. The United Arab Emirates is striving to mitigate the effects of global warming by launching numerous initiatives that contribute to reducing emissions. One of the main sources of these emissions in the UAE is the buildings where the cooling loads required by buildings in Dubai accounts for 60% of the summer peak electricity load. Thus it is important to propose solutions to decrease energy consumptions of these buildings. Therefore, this study aims to quantify the potential energy savings achievable by external shading devices.Item Energy saving by using Double Skin Façade for office buildings in the UAE(The British University in Dubai (BUiD), 2014-03) Ashour, MohamedThere is more demand on glazed façades for high-rise buildings which, increase cooling loads especially in hot and arid climate. Double skin façade is widely used to reduce energy loads and provide visually transparent façades, it has become more popular in cold climates because of the evident ability of the double skin façade to reduce heating loads, on the other hand many studies have shown potential energy savings by using double skin façade in hot climate as well, it is thought to be as a result of ventilating the channel between the external and internal façade. This study attempted to simulate the thermal performance of the double skin façade in high-rise office building in Dubai city, where temperature could reach over 42 ᵒC in summer. The study examined different parameters that could affect the performance of the double skin façade such as, channel width, glazing type, and natural ventilation mode. Results showed that double skin façade can reduce cooling loads regardless the channel was ventilated or not as result of reduced solar gain by the external façade. The results also showed up to 20% savings in cooling plant sensible annual load and 8% savings in total annual energy consumption, computer simulation were used to estimate thermal performance of the façade and also computational fluid dynamic analysis was used in a partial section of the model to simulate thermal behavior inside the channel. More comprehensive evaluation is recommended for double skin façade system, to balance between cost increase when adding another skin to the building and total running cost savings by reducing annual total energy consumption.