Failure Modes Effects and Criticality Analysis and Fault Tree Analysis Case Study of Waste Heat Recovery Plant in a Cement Factory, United Arab Emirates

dc.contributor.authorShanks, Kirk
dc.contributor.authorHamad, Abdallah
dc.contributor.authorAmeer, Alaa
dc.date.accessioned2025-08-12T16:47:59Z
dc.date.issued2020-02-06
dc.description.abstractThis article reports a case study of the appli cation of FMECA and FTA methods to inform the design of effective maintenance program for a waste heat recovery power plant in the hot arid climate of the United Arab Emirates. It illustrates the strengths and weaknesses of these approaches through a case study report of a live plant in a cement factory. The article highlights the implications and importance of plant-specific contextual factors in conducting quality FMECA and FTA.
dc.identifier.urihttps://bspace.buid.ac.ae/handle/1234/3261
dc.language.isoen_US
dc.titleFailure Modes Effects and Criticality Analysis and Fault Tree Analysis Case Study of Waste Heat Recovery Plant in a Cement Factory, United Arab Emirates
dc.typeArticle