The energy saving potential of using the optimum external fixed louvers configurations in an Office Building in UAE climate condition

dc.Location2011 HC 79 G47
dc.SupervisorProfessor Bassam Abu-Hijleh
dc.contributor.authorAl-Geresi, Shareef Yahia
dc.date.accessioned2013-05-21T10:35:50Z
dc.date.available2013-05-21T10:35:50Z
dc.date.issued2011-01
dc.description.abstractStudies on the effect of external fixed louvers shading device on office buildings energy performance in UAE climate condition have shown that the louvers application caused a significant energy saving potential for the South, East and West orientations. However, the different louvers configurations and properties estimate a different performance in energy saving. This research aimed to exploring the influence of changing the louvers Aspect Ratio AR, louvers color, louvers slat tilt angles and louvers material in the energy performance of office building in Dubai city. A virtual office unit model with the same parameters of existing office building in Dubai was used to evaluate the energy consumption performance of external fixed louvers for the South, North, East and West orientations. The IES-VE computer simulation software was used to predict the energy consumption in order to evaluate the effect of difference louvers configurations and properties in energy performance. This study found that the louvers shade application with the same AR value of Louvers Width / Lovers Spacing distance (LW/LS) results approximately the same effect in energy saving. This is important as we can focus on the effect of AR only without having to test the different combination of LS and LW that give similar AR. The study found that the optimum energy saving reduction was recorded by using lovers (AR=3.0) with semitransparent material with Visible Transmittance (VT) 50% was achieved 33.16% annual average energy saving comparison with the base case (without louvers shading and light dimming system) for the South orientation. The optimum louvers AR configuration was AR=3.0 with annual average percentage of reduction in energy saving 29.33%, 25.06% and 23.47% for the South, East and West orientations, respectively. The study found also that the changing in louvers AR is more efficient in energy saving than the changing in louvers angles.en_US
dc.identifier.other90029
dc.identifier.urihttp://bspace.buid.ac.ae/handle/1234/129
dc.language.isoenen_US
dc.publisherThe British University in Dubai (BUiD)en_US
dc.subjectoffice buildingsen_US
dc.subjectclimateen_US
dc.subjectUnited Arab Emirates (UAE)en_US
dc.subjectenergy performanceen_US
dc.subjectenergy savingen_US
dc.subjectDubaien_US
dc.subjectenergy consumptionen_US
dc.subjectlouvers configurationsen_US
dc.titleThe energy saving potential of using the optimum external fixed louvers configurations in an Office Building in UAE climate conditionen_US
dc.typeDissertationen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
90029.pdf
Size:
7.66 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: